Microsoft Sank a Data Centre in the Ocean – and It Worked Better (Project Natick)
In 2018 Microsoft sank 864 servers off Scotland for two years. They failed one-eighth as often as on land. Here's the story of Project Natick, and why it ended.
Watch the Short
The 60-second version is on YouTube. This article is the full story.
New Shorts every week on tech trivia, AI and gadgets.
Subscribe to TheTechPranaKey takeaways
- In June 2018 Microsoft sank a shipping-container-sized steel tube holding 864 servers 117 feet down off Scotland's Orkney Islands.
- Sealed with dry nitrogen and left untouched for two years, its servers failed at one-eighth the rate of an identical set-up on land.
- In 2024 Microsoft confirmed it isn't building underwater data centres anywhere – but says the lessons feed into its data centres on land.
Data centres are normally the most carefully guarded buildings on the planet: air-conditioned, dust-filtered and full of engineers swapping out failed parts. So in 2018, Microsoft did something that sounds like a joke. It put a data centre in a steel tube and dropped it to the bottom of the sea.
Two years later, it pulled the tube back up – and found the servers inside had held up far better than the ones on land.
The idea came from a submarine
Project Natick started in 2013 with a Microsoft employee, Sean James, who had served on a US Navy submarine. He wrote an internal paper arguing that the ocean could solve two of a data centre’s biggest problems.
- Cooling. Servers turn electricity into heat, and land data centres spend a lot of energy getting rid of it. The sea is cold, all the time, for free.
- Distance. About half the world’s population lives near a coast. A data centre just offshore sits close to the people using it, which means faster responses.
Microsoft’s research team liked the idea enough to try it.
Phase 1: a 105-day test off California
The first prototype was named Leona Philpot, after a character in Microsoft’s Halo games. In August 2015 it was lowered about 30 feet into the Pacific off the coast of California, and it ran for 105 days before being lifted out and shipped back to Microsoft’s Redmond campus for study.
It was small, with a single rack of computers, but it answered the first question: yes, a sealed data centre can work underwater.
Phase 2: 864 servers off Scotland
The second vessel was the real test. Named Northern Isles, it was built with the French naval engineering company Naval Group and was about the size of a 40-foot shipping container: roughly 12 metres long and 2.8 metres across.
Inside were 12 racks holding 864 servers and 27.6 petabytes of storage – Microsoft’s own comparison is enough for about 5 million movies.
In June 2018 it was lowered to the seabed 117 feet (about 36 metres) down at the European Marine Energy Centre, off Scotland’s Orkney Islands. A single cable to shore carried both its power and its internet connection. That power came from Orkney’s local grid, which runs on wind, solar, tidal and wave energy.
Two details made it unlike any data centre on land:
- No air. The tube was filled with dry nitrogen instead of oxygen.
- No people. Nobody could open it. If a server broke, it stayed broken.
Two years later: barnacles and a surprise
In July 2020, the team hauled Northern Isles back to the surface. The gleaming white tube came up coated in algae, barnacles and sea anemones.
Then came the result that made headlines. The underwater servers had failed at one-eighth the rate of a matching set of servers Microsoft had run on land for comparison. Put another way, for every eight servers that failed on land, about one failed under the sea.
Why did they last longer?
The team’s explanation, which Microsoft presented as its leading hypothesis, comes down to two things:
- Nitrogen instead of oxygen. Oxygen and humidity slowly corrode electronic parts. A dry nitrogen atmosphere is far gentler.
- No people. In a normal data centre, engineers walk around, swap parts and bump into equipment. Nobody touched the servers in the tube for two years.
The second point is a useful lesson for any data centre: every time a person opens a machine, something can go wrong.
So why aren’t our servers underwater?
Despite the results, Microsoft didn’t follow up with a fleet of undersea data centres. In June 2024, Noelle Walsh, who heads Microsoft’s cloud operations, told DatacenterDynamics that the company was not building subsea data centres anywhere in the world.
Microsoft didn’t call Natick a failure. It said the lessons, especially about reliability, low-oxygen environments and not disturbing servers, carry over to how it designs and runs its data centres on land.
There are some obvious practical reasons it stayed an experiment. A sealed tube can’t be upgraded or repaired, so every part has to be planned to last for its whole life. And modern AI data centres are enormous, using far more power than a shipping container could ever hold.
Quick recap
- 2013: Microsoft employee and ex-submariner Sean James proposes underwater data centres
- 2015: Leona Philpot prototype runs for 105 days off California
- June 2018: Northern Isles (864 servers) sinks 117 feet off Orkney, Scotland
- July 2020: retrieved; failure rate one-eighth that of the land comparison
- 2024: Microsoft confirms it isn’t building underwater data centres
Your turn: would you trust your data at the bottom of the sea? Watch the Short above and tell us in the YouTube comments.
Sources
- Microsoft: Project Natick (research site)
- Microsoft Research: Project Natick Phase 1
- Microsoft News: Microsoft finds underwater datacenters are reliable, practical and use energy sustainably (14 Sept 2020)
- Data Center Knowledge: Microsoft finds underwater data centers practical
- DatacenterDynamics: Microsoft confirms Project Natick underwater data center is no more (June 2024)
- Wikipedia: Project Natick